Compare commits

...
Author SHA1 Message Date
Frank fcf94562d1 feat(frank-dragoon): open the NPU node the way rootless can actually reach it
The armed boot reached the engine and died in its own preflight:

  halogen npu: /dev/accel/accel0 is here, but this process cannot open it
    (crw-rw---- nobody:nogroup).

The node is root:render 0660 and a rootless container maps exactly one uid/gid,
so `render` is unmapped inside it and `--group-add keep-groups` — the vendor's
advice, and the ComfyUI pattern for /dev/kfd — cannot grant a group the
namespace does not map. Measured 2026-10-19 from a `dank` shell already in
`render`: without the flag denied, with the flag denied, with the udev mode
0666 the open succeeds (OPEN_OK). Same wall 99-comfyui-gpu-access.rules already
solved for the GPU compute nodes, so the accel node gets its counterpart:

  dankclaw/udev/98-halogen-npu-access.rules — KERNEL=="accel[0-9]*",
  SUBSYSTEM=="accel", MODE="0666"

The deployer installs the rule, reloads rules, re-triggers the node and only
then checks the mode; the serve script refuses any node that is not
other-writable, naming the rule, so this cannot return as a crash loop (189
restarts while chat was down is the failure mode being closed).

Both checks read the permission bit directly: `[ -o FILE ]` is not
"other-writable" — it means "exists" and `-o` doubles as the OR operator inside
test, which is why the first cut of the gate refused everything.

Dragoon seam: 33 -> 35 tests. The fixture node is 0666 like the installed one,
a 0660 node is refused with the rule named and nothing rendered, and the rule
file's shape plus the deployer's install/trigger are asserted.
2026-10-19 22:35:06 -07:00
Frank 3ef711f146 fix(deploy): the dragoon gate reads the deployer's own payload-dir twin
The containment gate added in #44 parsed scripts/frank-dragoon.env through a
$CHECKOUT variable that does not exist in deploy-remote.sh, so the very next
deploy died at `set -u` before it touched the unit:

  ./scripts/deploy-remote.sh: line 1445: CHECKOUT: unbound variable

deploy-remote.sh runs from the checkout root and every other path in that block
is a parity-twin default (LLM_DRAGOON_CKPT/_VISION/_TOK_DIR), so the payload dir
gets the same treatment: LLM_DRAGOON_MODEL_DIR, defaulted to the deployed path,
compared directly. The seam now asserts that twin against the env file next to
the NPU twins it already checks, and the containment comparison itself is
verified both ways (inside accepted; the old outside path and a shared-prefix
sibling both refused).
2026-10-19 21:48:47 -07:00
dank 823fd52d0e Merge pull request 'fix(frank-dragoon): stage the NPU lane inside the payload mount' (#44) from feat/frank-dragoon-npu-lane into main 2026-10-19 21:46:25 -07:00
Frank bda011d26f docs(vault): the NPU lane's one door into the container, and the pin that landed
frank-dragoon's lane section: the staging dir must live inside the payload dir
(the image ships no /models, so a nested :ro bind has no mountpoint to land on),
the entrypoint's rejection of HALOGEN_NPU_DIR, and the fabric-clock paragraph
corrected — the vendor's root host unit is installed and reports `held (manual)`
as of today, so "nothing is held" is retired along with the hand-write it
replaced.

dankclaw-iommu-translation-off: the deferred `pp_dpm_fclk` pin is no longer
deferred; the fact is owned by [[frank-dragoon]] and this page links it.
2026-10-19 21:43:36 -07:00
6 changed files with 120 additions and 17 deletions

No files matched your search

+26
View File
@@ -0,0 +1,26 @@
# /etc/udev/rules.d/98-halogen-npu-access.rules
#
# Why the NPU node is world-writable: `frank-dragoon` runs rootless podman under a
# unit with `User=dank`, and the container's user namespace maps exactly one uid and
# one gid (dank). `/dev/accel/accel0` is `root:render 0660`, so inside the container
# the node reads `nobody:nogroup` and the engine dies with its own diagnosis:
#
# halogen npu: /dev/accel/accel0 is here, but this process cannot open it
# (crw-rw---- nobody:nogroup).
#
# `--group-add keep-groups` is the vendor's advice and it does NOT work in this
# shape: measured 2026-10-19 from the host as a `dank` shell that was already in
# `render`, with and without the flag, the node still read `nobody:nogroup` and the
# open was refused — an unmapped gid cannot be granted to a process inside a
# namespace that does not map it. Same conclusion `99-comfyui-gpu-access.rules`
# reached for `/dev/kfd` from the systemd-user-spawn direction: the mode is the only
# spawn-context-independent door short of running the stack rootful.
#
# Blast radius: any process in this host's single uid domain (every rootless
# container here shares it) can submit to the XDNA2 NPU. The NPU holds no user data
# and no privileged context — the same trade already accepted for the GPU compute
# nodes beside it. Installed by `deploy-remote.sh` when the NPU lane is armed and left
# in place afterwards — the mode costs nothing while the lane is idle. `serve-frank-dragoon.sh`
# refuses to arm the lane on a node that is not other-accessible, so a host that lost this
# file fails loudly at boot instead of crash-looping.
KERNEL=="accel[0-9]*", SUBSYSTEM=="accel", MODE="0666"
+19 -4
View File
@@ -1329,6 +1329,9 @@ deploy_anubis() {
# port gate is the same as every cutover since 2026-09-16: nothing
# starts until 7770 is released.
LLM_DRAGOON_IMAGE="${LLM_DRAGOON_IMAGE:-ghcr.io/peonist-ai/halogen-flash-server@sha256:0c61bf84ac22308a53f5d1ca6b86806702d7039e5ebc51cae4c66621b92fe04a}"
# The payload dir is its own twin because the NPU lane's containment gate below
# reads it; every artifact path under it stays a full literal as usual.
LLM_DRAGOON_MODEL_DIR="${LLM_DRAGOON_MODEL_DIR:-/home/dank/models/halogen-v2-abliterated}"
LLM_DRAGOON_CKPT="${LLM_DRAGOON_CKPT:-/home/dank/models/halogen-v2-abliterated/qwen38-flash-next-v2-abliterated.hgn}"
LLM_DRAGOON_CKPT_BYTES="${LLM_DRAGOON_CKPT_BYTES:-66687678432}"
LLM_DRAGOON_NGRAM="${LLM_DRAGOON_NGRAM:-/home/dank/models/halogen-v2-abliterated/qwen38-flash-next-ngram.hgn}"
@@ -1441,16 +1444,28 @@ deploy_llm_dragoon() {
# payload dir. A staging dir outside it needs a nested bind whose
# mountpoint runc cannot create through a read-only parent, so the
# parity twin of the serve gate refuses the shape before the restart.
npu_model_dir="$(sed -nE 's/^FRANK_DRAGOON_MODEL_DIR=(.*)$/\1/p' \
"$CHECKOUT/scripts/frank-dragoon.env" | tail -1)"
if [[ -n "$npu_model_dir" && "$LLM_DRAGOON_NPU_DIR/" != "$npu_model_dir"/* ]]; then
echo "ERROR: NPU staging dir $LLM_DRAGOON_NPU_DIR is outside the payload dir $npu_model_dir — the lane's files reach the container only through the read-only /models mount" >&2
if [[ "$LLM_DRAGOON_NPU_DIR/" != "$LLM_DRAGOON_MODEL_DIR"/* ]]; then
echo "ERROR: NPU staging dir $LLM_DRAGOON_NPU_DIR is outside the payload dir $LLM_DRAGOON_MODEL_DIR — the lane's files reach the container only through the read-only /models mount" >&2
return 1
fi
if [[ ! -e "$LLM_DRAGOON_DEV_ACCEL" ]]; then
echo "ERROR: NPU node $LLM_DRAGOON_DEV_ACCEL absent — amdxdna is not bound (is iommu=pt still on the boot line?)" >&2
return 1
fi
# Access, not existence: a rootless container cannot open a root:render
# 0660 node (its namespace maps one uid/gid, and keep-groups cannot grant
# an unmapped gid — measured 2026-10-19). Install the mode rule, re-trigger
# the node, then PROVE the node is other-accessible before the restart.
run_privileged install -m 0644 dankclaw/udev/98-halogen-npu-access.rules \
/etc/udev/rules.d/98-halogen-npu-access.rules
run_privileged udevadm control --reload-rules
run_privileged udevadm trigger --sysname-match="$(basename "$LLM_DRAGOON_DEV_ACCEL")"
# (`-o FILE` is not "other-writable" — it means "exists", and `-o` is also
# the OR operator inside test), so the bit is read straight off the mode.
if [[ $(( 8#$(stat -c '%a' "$LLM_DRAGOON_DEV_ACCEL") & 8#2 )) -eq 0 ]]; then
echo "ERROR: $LLM_DRAGOON_DEV_ACCEL is still $(stat -c '%a %U:%G' "$LLM_DRAGOON_DEV_ACCEL") after installing the access rule — the lane cannot open it rootless" >&2
return 1
fi
for xl in libxrt_coreutil.so.2 libxrt_core.so.2 libxrt_driver_xdna.so.2; do
if [[ ! -e "$LLM_DRAGOON_XRT_DIR/$xl" ]]; then
echo "ERROR: XRT NPU library $LLM_DRAGOON_XRT_DIR/$xl absent (Ubuntu libxrt2 + libxrt-npu2)" >&2
+12
View File
@@ -165,6 +165,18 @@ if [ -n "$NPU_MODELS" ]; then
echo "frank-dragoon: $DEV_ACCEL missing — the NPU lane needs the amdxdna node (is iommu=pt still on the boot line?)" >&2
exit 1
fi
# Existence is not access. This endpoint runs rootless, so the container's
# namespace maps exactly one uid/gid (dank) and a root:render 0660 node reads
# `nobody:nogroup` inside it — the engine then dies naming the node itself
# (measured 2026-10-19). --group-add keep-groups cannot help: an unmapped gid
# cannot be granted into a namespace that does not map it, verified with and
# without the flag from a shell already in `render`. The door is the udev mode.
# NB: `[ -o FILE ]` is NOT "other-writable" — it means "exists", and `-o` is
# also the OR operator inside test — so the permission bit is read directly.
if [ $(( 8#$(stat -c '%a' "$DEV_ACCEL") & 8#2 )) -eq 0 ]; then
echo "frank-dragoon: $DEV_ACCEL is $(stat -c '%a %U:%G' "$DEV_ACCEL") — a rootless container cannot open it; install dankclaw/udev/98-halogen-npu-access.rules and re-trigger udev (sudo udevadm control --reload-rules && sudo udevadm trigger --sysname-match=accel0)" >&2
exit 1
fi
for M in ${NPU_MODELS//,/ }; do
if [ ! -d "$NPU_DIR/$M" ]; then
echo "frank-dragoon: NPU model $M not staged in $NPU_DIR;" >&2
@@ -215,9 +215,10 @@ is in `render`, so a quadlet needs `AddDevice=/dev/accel/accel0` +
`GroupAdd=keep-groups`. **No NPU endpoint is deployed** — stays the
history of the retired endpoint; what changed is only its precondition.
**Deliberately deferred:** the `pp_dpm_fclk` pin (level 7, 2000 MHz) from the issue's
co-run step. Pinning the fabric clock changes iGPU timing for every workload, and
nothing co-runs on the NPU yet; it goes in when an NPU endpoint actually exists.
**The `pp_dpm_fclk` pin (level 7, 2000 MHz) went in on 2026-10-19**, with the first thing that needed it: the
vendor's root host unit, installed and enabled by `frank-dragoon`'s deployer while its NPU lane is named. Pinning
the fabric clock changes iGPU timing for every workload, which is exactly why it waited for a co-run to exist; the
law, the hold and the serve-side re-check live in [[frank-dragoon]].
PerfOpt still needs Linux 7.4 — `7.0.0-38-generic` has zero `perfopt` symbols and the
26.04 archive caps at `7.0.0-38.38`.
+26 -10
View File
@@ -219,7 +219,7 @@ created it — earlier topologies in .
- Deploy waits for :7770 to be free: a rootless container binds it at CREATE and exits 126, and a
leftover Quadlet beside the root unit guarantees the race.
## The NPU lane (present in the image, not enabled)
## The NPU lane (XDNA2, armed by one env var)
XDNA2 executes only vendor-precompiled AIE partition programs — that is the wall the TTS attempt died at
([[Frank TTS]]) — and flash-server ships those programs. `HALOGEN_NPU_MODELS=<names>` starts a second engine **in the
@@ -235,11 +235,20 @@ Embedding contract on that lane: `POST /v1/embeddings`, `model: "qwen3-embedding
(`Instruct: …\nQuery:…`), `base64` accepted, and LangChain's `OpenAIEmbeddings` needs
`check_embedding_ctx_length=False`.
Four prerequisites the trio does not satisfy today, from the vendor's own host list — and this box is one of the two
configurations they test (Ubuntu 26.04's XRT 2.21 `libxrt2`+`libxrt-npu2`, the kernel's `amdxdna`, `iommu=pt`):
Four host prerequisites, each refused **by name** in the serve script and mirrored in `deploy_llm_dragoon` — a
precondition that surfaces as an engine crash-loop is a gate that was never written. All four are satisfied on this
box as of 2026-10-19; the endpoint still runs with the lane **off** until that day's mount fix merges, and the first
armed boot's evidence lands here with it:
1. `--device /dev/accel/accel0` plus `--group-add keep-groups` (the pattern ComfyUI uses for `/dev/kfd`; `dank` is
already in `render`).
1. `--device /dev/accel/accel0` **and** a node the container's namespace can open. `/dev/accel/accel0` is
`root:render 0660` and a rootless namespace maps exactly one uid/gid, so the engine's own first words are
*"this process cannot open it (crw-rw---- nobody:nogroup)"*. `--group-add keep-groups` — the vendor's advice and
the ComfyUI pattern for `/dev/kfd` — is **dead in this shape**: measured 2026-10-19 from a `dank` shell already
in `render`, with and without the flag the node stayed `nobody:nogroup` and the open was refused; an unmapped
gid cannot be granted across a namespace that does not map it. The door is the udev mode
(`dankclaw/udev/98-halogen-npu-access.rules`, installed and re-triggered by the deployer, `0666` like the GPU
compute nodes beside it); the serve script refuses any node that is not other-accessible, so the fault cannot
return as a crash-loop.
2. The host's XRT reachable inside: there is **no `/opt/xilinx/xrt`** here — distro packages put the three files the
container needs (`libxrt_coreutil.so.2`, `libxrt_core.so.2`, `libxrt_driver_xdna.so.2`) in
`/usr/lib/x86_64-linux-gnu`, where all three exist.
@@ -248,11 +257,18 @@ configurations they test (Ubuntu 26.04's XRT 2.21 `libxrt2`+`libxrt-npu2`, the k
engine holds the clock itself only when it runs as root with `/sys` mounted; `frank-dragoon` is a **rootless**
`podman run` under `User=dank`, so the path is the vendor's root host unit (`deploy/host/halogen-fabric-clock`) —
which is exactly the `pp_dpm_fclk` level-7 pin deferred in [[dankclaw-iommu-translation-off]] with the words "it
goes in when an NPU endpoint actually exists". Held: about a watt. Unheld: the hang. Measured 2026-10-19 nothing
is held (fabric DPM lists 400–2000 MHz with no forced level, graphics clock sitting at 857 of 2900 MHz).
4. `HALOGEN_DOWNLOAD=peonist-ai/halogen-qwen3.8-flash-next` on a boot with a **writable** `/models/npu` — the payload
mount is `:ro` by law, so the programs land via a throwaway writable run or a dedicated read-write bind for that
one subdirectory; the vendor notes a read-only volume works but re-runs the conversion at every start.
goes in when an NPU endpoint actually exists". Held: about a watt. Unheld: the hang. The deployer installs and
enables that unit whenever the lane is named, and `halogen-fabric-clock status` reports `held (manual)` here as of
2026-10-19; the serve script re-reads the same two sysfs files at every start and refuses by name if the top level
is not the starred one, because a hold done by hand is a countdown to the next reboot.
4. The programs are staged under `$FRANK_DRAGOON_NPU_DIR`, which **must sit inside the payload dir**
(`/home/dank/models/halogen-v2-abliterated/npu`): the payload's read-only mount is the container's only handle on
`/models`. A nested bind at `/models/npu` cannot work — the image ships no `/models`, so runc has to `mkdir` the
mountpoint through a read-only parent and dies at container init (measured 2026-10-19: 52 crash-loop restarts with
chat down before the mount shape was fixed). `HALOGEN_NPU_DIR` is no escape; the shipped entrypoint rejects it by
name ("our NPU models live under `/models/npu/<id>/`"). Nothing downloads at boot — `HALOGEN_DOWNLOAD` stays
unset, so the container opens no outbound connection; `scripts/download-frank-dragoon-npu.sh` pins every file by
size and sha256 against the catalog and the payload mount carries the tree in.
Price: the programs and their weights sit in host RAM beside the 62.9 GiB of locked weights ("a few GB in all" for
the default set; ~1.1 GiB for `embeddinggemma-2`), and **the Flash model decodes slower while the NPU works** — same
+33
View File
@@ -30,6 +30,7 @@ setup() {
HOST_UNIT="$ROOT/dankclaw/host/halogen-fabric-clock"
HOST_SERVICE="$ROOT/dankclaw/host/halogen-fabric-clock.service"
NPU_FETCH="$ROOT/scripts/download-frank-dragoon-npu.sh"
NPU_RULE="$ROOT/dankclaw/udev/98-halogen-npu-access.rules"
BUILD="$ROOT/scripts/build-rocmfpx.sh"
TEST_TMP="$(mktemp -d)"
touch "$TEST_TMP/empty.env"
@@ -357,6 +358,9 @@ $(cat "$TEST_TMP/serve.log")"
npu_models="$(sed -nE 's/^HALOGEN_NPU_MODELS=(.*)$/\1/p' "$ENV_FILE")"
grep -qF "LLM_DRAGOON_NPU_DIR=\"\${LLM_DRAGOON_NPU_DIR:-$npu_dir}\"" "$DEPLOYER"
grep -qF "LLM_DRAGOON_NPU_MODELS=\"\${LLM_DRAGOON_NPU_MODELS:-$npu_models}\"" "$DEPLOYER"
# The deployer's own copy of the payload dir is what the lane's containment
# gate compares against — a stale twin would wave a bad staging path through.
grep -qF "LLM_DRAGOON_MODEL_DIR=\"\${LLM_DRAGOON_MODEL_DIR:-$dir}\"" "$DEPLOYER"
net="$(sed -nE 's/^FRANK_DRAGOON_NETWORK=(.*)$/\1/p' "$ENV_FILE")"
grep -qF "LLM_DRAGOON_NETWORK=\"\${LLM_DRAGOON_NETWORK:-$net}\"" "$DEPLOYER"
}
@@ -415,7 +419,10 @@ $(cat "$TEST_TMP/serve.log")"
# refused BY NAME instead of surfacing as an engine crash-loop.
npu_fixture() {
# 0666 like the installed node: a rootless container's namespace cannot open
# the stock root:render 0660 mode, and the serve gate checks exactly that.
touch "$TEST_TMP/accel0"
chmod 666 "$TEST_TMP/accel0"
mkdir -p "$TEST_TMP/xrt"
for l in libxrt_coreutil.so.2 libxrt_core.so.2 libxrt_driver_xdna.so.2; do
touch "$TEST_TMP/xrt/$l"
@@ -523,6 +530,32 @@ $(cat "$TEST_TMP/serve.log")"
[[ "$output" == *"iommu=pt"* ]]
}
@test "the lane refuses an NPU node the container namespace could not open, and names the rule" {
# Stock Debian mode is root:render 0660. The engine's own first words on such
# a node are "this process cannot open it (crw-rw---- nobody:nogroup)" and no
# flag fixes a mode an unmapped gid cannot cross (keep-groups measured dead
# 2026-10-19), so the unit refuses instead of crash-looping 189 times.
podman_stub
good_env
npu_fixture
chmod 660 "$TEST_TMP/accel0"
run_with_log
[ "$status" -ne 0 ]
[[ "$output" == *"$TEST_TMP/accel0 is 660"* ]]
[[ "$output" == *"98-halogen-npu-access.rules"* ]]
[[ "$output" != *"--device"* ]]
}
@test "the NPU access rule is the accel counterpart of the GPU compute rule" {
[ -f "$NPU_RULE" ]
grep -qE '^KERNEL=="accel\[0-9\]\*", SUBSYSTEM=="accel", MODE="0666"$' "$NPU_RULE"
# The deployer installs the rule and re-triggers the node BEFORE it trusts
# the mode, so a machine that never had it self-heals instead of refusing.
grep -qE '98-halogen-npu-access\.rules' "$DEPLOYER"
grep -qE 'udevadm control --reload-rules' "$DEPLOYER"
grep -qE 'udevadm trigger --sysname-match=' "$DEPLOYER"
}
@test "the lane refuses when an XRT NPU library is missing" {
podman_stub
good_env