Files
serverAppConfigs/serverAppConfigs-docs/LLM/frank-npu.md
T
Frank 55f87fcdce llm: retire the trio service names — fleet services renamed to frank-archon/frank-dragoon/frank-zealot
The 2026-10-09 wire aliases become the service names everywhere:
systemd units, serve scripts, env files and FRANK_* variables,
deploy-plan/deploy-remote service keys, container names, Prometheus
job names + alert rules, Grafana dashboard queries, bats seams,
runbook filenames, homepage/AGENTS lore, and historical prose.
Rollback tags renamed in lockstep. Residue in the tree: zero.
Retired frank-medium/small/npu names are history and stay.

Known casualty: scripts/patches/*.patch context lines were rewritten;
those retired-era vLLM-fork patches no longer apply byte-exact.
2026-10-10 17:03:14 -07:00

6.6 KiB
Raw Blame History

type, title, description, tags, timestamp
type title description tags timestamp
reference frank-npu (retired) — FLM NPU endpoint on Dankclaw The retired FastFlowLM endpoint on Dankclaw's XDNA2 NPU — what it served, why it died on 2026-09-11 with the amd_iommu=off decision, and where every dependent route went.
flm
fastflowlm
xdna2
npu
dankclaw
frank-npu
retired
2026-09-11

frank-npu — the retired FLM NPU endpoint

RETIRED 2026-09-11. The endpoint is gone by operator decision, together with the IOMMU configuration it required — see dankclaw-iommu-translation-off. The service unit, env file and serve script are staged in serverAppConfigs/.AGENTTRASH/ (suffixed .flm-npu), and the host unit is stopped and masked.

The third inference endpoint on Dankclaw: a FastFlowLM (FLM) v1.0.1 server (/usr/bin/flm, dpkg fastflowlm) on the XDNA2 NPU (50 TOPS), serving the whole local model registry on port 7771 and routing per request by the exact FLM registry tag. Its one capability the iGPU fleet lacked was sight — and briefly sound: the Gemma4 E4B IT NPU2 pack carries both a vision and an audio tower, which is why the service ran that pack rather than the uncensored-but-text-only alternative.

This page is kept as the retirement record. The operational detail below was live-verified while the service ran and remains accurate about FLM's shape.

Why it is retired

The replacement large-model runtime is worth 13–16 % of prefill if the kernel boots with amd_iommu=off instead of iommu=pt, measured by the upstream project on this exact silicon. That single flag is the whole decision:

  • With IOMMU off there is no PASID/SVA state, and the XDNA2 driver cannot hand out /dev/accel/accel0 — every open fails with err=-19 ("No such device"). That is precisely the failure the endpoint was rescued from on 2026-08-30, recorded in the next section.
  • iommu=pt is not a middle ground for the NPU and the prefill number: the passthrough domain still costs the prefill throughput the vendor measured.
  • The operator chose prefill, so the NPU endpoint goes.

Consequences accepted at retirement: audio input left the fleet with no replacement (halogen reads images only, no audio or video), and the surviving image path is halogen's vision tower on frank-dragoon.

Where its routes went

consumer setting now
Hermes auxiliary.vision dankclaw-large / frank-dragoon (halogen vision tower)
Hermes auxiliary.title_generation dankserver-small / frank-zealot
harness (~/.omp/agent/models.yml) modelRoles.vision llamacpp (dankclaw) / frank-dragoon
harness modelRoles.tiny llamacpp (dankserver) / frank-zealot
harness modelRoles.task llamacpp (dankclaw) / frank-dragoon:medium

The flm (dankclaw-npu) provider block was removed from the harness model config, and the dankclaw-npu provider from Hermes's live config.yaml.

What it was

Field Value
Runtime FLM v1.0.1 (/usr/bin/flm, dpkg fastflowlm) on the XDNA2 NPU
Service frank-npu.service (systemd system unit, User=dank, Restart=on-failure, RestartSec=10, LimitMEMLOCK=infinity)
Files (archived) scripts/frank-npu.env, scripts/serve-frank-npu.sh, scripts/frank-npu.service
Port 7771 on 0.0.0.0
Power mode FLM_PMODE=turbo — nothing else used the NPU, so the top power mode cost no neighbour anything
Context FLM_CTX_LEN=131072 (128K, the verified maximum on this box)
Vision/audio FLM_ASR=0; the E4B pack answers images through its own vision tower, and FLM_ASR=1 would have added Whisper-V3-Turbo-NPU2 (+0.62 GB) and /v1/audio/transcriptions

The serve script exported FLM_CONFIG_PATH=/home/dank/.config/flm/model_list.json and FLM_XCLBIN_PATH=/home/dank/.config/flm/xclbins, with kernels symlinked from /opt/fastflowlm/share/flm/xclbins/ into the per-pack directories, so a tag swap was an env-file edit rather than a script edit.

API contract (as it behaved)

  • The endpoint served the whole local registry (36 tags at first deploy) on one port; /v1/models listed them all. Chat completions routed per request by the exact registry tag in the model field — never a service alias.
  • Unknown tags did not 404: /v1/chat/completions answered HTTP 200 with a flat error body {"error":"Failed to load <tag> model!"} and no choices. Status-code-only clients silently got an empty response.
  • Health was GET /v1/version; FLM has no /health route.
  • The NPU is a single-lane device — generations serialized FIFO. It was a background/triage endpoint, not interactive multi-user chat.

The IOMMU/SVA root cause (first deploy crashed, fixed 2026-08-30)

First deploy crash-looped every 10 s with Error: Open /dev/accel/accel0 failed (err=-19): No such device. The chain, all live-verified on the host:

  1. amdxdna_drm_open failed SVA bind with ret -19 for every client — the XDNA2 driver cannot hand out the accel device without PASID/SVA.
  2. SVA requires the AMD IOMMU to be enabled, and the kernel cmdline then carried iommu=off. With IOMMU off there are no IOMMU groups and no PASID state; PASIDCtl: Enable- was observed on 0000:c5:00.1.
  3. The fix was iommu=pt: passthrough keeps the iGPU default domain identity-mapped (no DMA-translation overhead for frank-dragoon) while enabling the IOMMU hardware and PASID that the driver's SVA bind needs.
  4. Post-boot verification: /sys/kernel/iommu_groups/ populated (30 groups), zero SVA bind device failed entries since boot, accel0 recreated at boot, service active with NRestarts=0.

The same root cause explained the older amdgpu 0000:c4:00.0: no vmid pasid mapping supported kernel line — a consequence of IOMMU-off, not a GPU fault.

The standing rule this produced — "never set iommu=off on this host again" — has been superseded: the NPU it protected is retired by decision, and amd_iommu=off is now intentional. See dankclaw-iommu-translation-off for the current posture and how to revert it.

Client wiring (historical)

The pi/harness model config registered this endpoint with the exact FLM registry tag as the model id and baseUrl http://192.168.0.143:7771/v1. Both that provider block and Hermes's dankclaw-npu provider were removed at retirement; the routes are mapped in the table above.

Citations