--- type: reference title: frank-npu (retired) — FLM NPU endpoint on Dankclaw description: The retired FastFlowLM endpoint on Dankclaw's XDNA2 NPU — what it served, why it died on 2026-09-11 with the amd_iommu=off decision, and where every dependent route went. tags: - flm - fastflowlm - xdna2 - npu - dankclaw - frank-npu - retired timestamp: 2026-09-11 --- # frank-npu — the retired FLM NPU endpoint > **RETIRED 2026-09-11.** The endpoint is gone by operator decision, together > with the IOMMU configuration it required — see > [[dankclaw-iommu-translation-off]]. The service unit, env file and serve > script are staged in `serverAppConfigs/.AGENTTRASH/` (suffixed `.flm-npu`), > and the host unit is stopped and masked. The third inference endpoint on Dankclaw: a FastFlowLM (FLM) v1.0.1 server (`/usr/bin/flm`, dpkg `fastflowlm`) on the **XDNA2 NPU** (50 TOPS), serving the whole local model registry on port 7771 and routing per request by the exact FLM registry tag. Its one capability the iGPU fleet lacked was **sight** — and briefly **sound**: the Gemma4 E4B IT NPU2 pack carries both a vision and an audio tower, which is why the service ran that pack rather than the uncensored-but-text-only alternative. This page is kept as the retirement record. The operational detail below was live-verified while the service ran and remains accurate about FLM's shape. ## Why it is retired The replacement large-model runtime is worth **13–16 % of prefill** if the kernel boots with `amd_iommu=off` instead of `iommu=pt`, measured by the upstream project on this exact silicon. That single flag is the whole decision: - With IOMMU off there is no PASID/SVA state, and the XDNA2 driver cannot hand out `/dev/accel/accel0` — every open fails with `err=-19` ("No such device"). That is precisely the failure the endpoint was rescued from on 2026-08-30, recorded in the next section. - `iommu=pt` is not a middle ground for the NPU *and* the prefill number: the passthrough domain still costs the prefill throughput the vendor measured. - The operator chose prefill, so the NPU endpoint goes. Consequences accepted at retirement: **audio input left the fleet with no replacement** (halogen reads images only, no audio or video), and the surviving image path is halogen's vision tower on `frank-dragoon`. ## Where its routes went | consumer | setting | now | |---|---|---| | Hermes | `auxiliary.vision` | `dankclaw-large` / `frank-dragoon` (halogen vision tower) | | Hermes | `auxiliary.title_generation` | `dankserver-small` / `frank-zealot` | | harness (`~/.omp/agent/models.yml`) | `modelRoles.vision` | `llamacpp (dankclaw)` / `frank-dragoon` | | harness | `modelRoles.tiny` | `llamacpp (dankserver)` / `frank-zealot` | | harness | `modelRoles.task` | `llamacpp (dankclaw)` / `frank-dragoon:medium` | The `flm (dankclaw-npu)` provider block was removed from the harness model config, and the `dankclaw-npu` provider from Hermes's live `config.yaml`. ## What it was | Field | Value | |---|---| | Runtime | FLM v1.0.1 (`/usr/bin/flm`, dpkg `fastflowlm`) on the XDNA2 NPU | | Service | `frank-npu.service` (systemd **system** unit, `User=dank`, `Restart=on-failure`, `RestartSec=10`, `LimitMEMLOCK=infinity`) | | Files (archived) | `scripts/frank-npu.env`, `scripts/serve-frank-npu.sh`, `scripts/frank-npu.service` | | Port | `7771` on `0.0.0.0` | | Power mode | `FLM_PMODE=turbo` — nothing else used the NPU, so the top power mode cost no neighbour anything | | Context | `FLM_CTX_LEN=131072` (128K, the verified maximum on this box) | | Vision/audio | `FLM_ASR=0`; the E4B pack answers images through its own vision tower, and `FLM_ASR=1` would have added Whisper-V3-Turbo-NPU2 (+0.62 GB) and `/v1/audio/transcriptions` | The serve script exported `FLM_CONFIG_PATH=/home/dank/.config/flm/model_list.json` and `FLM_XCLBIN_PATH=/home/dank/.config/flm/xclbins`, with kernels symlinked from `/opt/fastflowlm/share/flm/xclbins/` into the per-pack directories, so a tag swap was an env-file edit rather than a script edit. ## API contract (as it behaved) - The endpoint served the **whole local registry** (36 tags at first deploy) on one port; `/v1/models` listed them all. Chat completions routed per request by the exact registry tag in the `model` field — never a service alias. - **Unknown tags did not 404**: `/v1/chat/completions` answered HTTP 200 with a flat error body `{"error":"Failed to load model!"}` and no `choices`. Status-code-only clients silently got an empty response. - Health was `GET /v1/version`; FLM has **no `/health` route**. - The NPU is a single-lane device — generations serialized FIFO. It was a background/triage endpoint, not interactive multi-user chat. ## The IOMMU/SVA root cause (first deploy crashed, fixed 2026-08-30) First deploy crash-looped every 10 s with `Error: Open /dev/accel/accel0 failed (err=-19): No such device`. The chain, all live-verified on the host: 1. `amdxdna_drm_open` failed **SVA bind with ret -19** for every client — the XDNA2 driver cannot hand out the accel device without PASID/SVA. 2. SVA requires the AMD IOMMU to be enabled, and the kernel cmdline then carried `iommu=off`. With IOMMU off there are no IOMMU groups and no PASID state; `PASIDCtl: Enable-` was observed on `0000:c5:00.1`. 3. The fix was `iommu=pt`: passthrough keeps the iGPU default domain identity-mapped (no DMA-translation overhead for `frank-dragoon`) while enabling the IOMMU hardware and PASID that the driver's SVA bind needs. 4. Post-boot verification: `/sys/kernel/iommu_groups/` populated (30 groups), zero `SVA bind device failed` entries since boot, `accel0` recreated at boot, service active with `NRestarts=0`. The same root cause explained the older `amdgpu 0000:c4:00.0: no vmid pasid mapping supported` kernel line — a consequence of IOMMU-off, not a GPU fault. **The standing rule this produced — "never set `iommu=off` on this host again" — has been superseded**: the NPU it protected is retired by decision, and `amd_iommu=off` is now intentional. See [[dankclaw-iommu-translation-off]] for the current posture and how to revert it. ## Client wiring (historical) The pi/harness model config registered this endpoint with the **exact** FLM registry tag as the model `id` and `baseUrl` `http://192.168.0.143:7771/v1`. Both that provider block and Hermes's `dankclaw-npu` provider were removed at retirement; the routes are mapped in the table above. ## Citations - [FastFlowLM](https://github.com/FastFlowLM/FastFlowLM) — FLM runtime and NPU model packs - [[dankclaw-iommu-translation-off]] — the decision that retired this endpoint - [[halogen-flash-server]] — the surviving image-input path